pump knob

Aim

This study aimed to evaluate the efficacy of the resin hemoperfusion device (HA380 hemoperfusion cartridge) on inflammatory responses during adult cardiopulmonary bypass (CPB). 

Methods

Sixty patients undergoing surgical valve replacement were randomized into the HP group (n = 30) with an HA380 hemoperfusion cartridge in the CPB circuit or the control group (n = 30) with the conventional CPB circuit. The results of routine blood tests, blood biochemical indexes, and inflammatory factors were analyzed at V0 (pre-CPB), V1 (CPB 30 min), V2 (ICU 0 h), V3 (ICU 6 h), and V4 (ICU 24 h).

Results

The HP group had significantly lower levels of IL-6, IL-8, and IL-10. Significant estimation of group differences in the generalized estimating equation (GEE) models was also observed in IL-6 and IL-10. The HP group had significantly lower levels of creatinine (Cr), aminotransferase (AST), and total bilirubin (TBil) compared to the control group. The estimation of differences of Cr, AST, and TBil all reached statistical significance in GEE results. The HP group had significantly less vasopressor requirement and shorter mechanical ventilation time and ICU stay time as compared to the control group.

Conclusion

The HA380 hemoperfusion cartridge could effectively reduce the systemic inflammatory responses and improve postoperative recovery of patients during adult CPB.