BACKGROUND:

Transcatheter aortic valve replacement (TAVR) can be complicated with a high-degree atrioventricular block requiring a permanent pacemaker (PPM) in 5% – 25% of patients. Association between body mass index (BMI) and pacemaker implantation has not been extensively studied. We compared standard BMI classes with the odds of requiring a PPM implantation in patients undergoing TAVR with Edwards SAPIEN™ 3 valves (ESV3) (Edwards Lifesciences, Irvine, CA, USA).

METHODS:

Our study involved a single-center retrospective cohort analysis of 449 patients undergoing TAVR from December 2012 to April 2018. First, we excluded patients with a TAVR procedure done with valves other than the ESV3 (127 patients). Second, patients with a prior PPM or an implantable cardioverter-defibrillator (37 patients) were excluded. Finally, patients with an aborted procedure and surgical conversion were excluded (16 patients). The final sample size was 269. The primary outcome was pacemaker implantation. Statistical analysis was done using the Chi-square test, T-test, and adjusted logistic regression.

RESULTS:

Of the 269 patients (50.6% males; mean age of 79.5 ± 8.7 years; mean Society of Thoracic Surgeons (STS) score: 6.2), pacemaker implantation was performed in 17 patients (6.3%). Time to pacemaker implantation was 1.3 days. Patients were divided into four categories based on their BMI: as underweight (BMI < 25; 67 patients), normal (BMI: 25 to ≤ 30; 87 patients), overweight (BMI: 30 to ≤ 35; 60 patients), and obese (BMI ≥ 35; 55 patients). Pacemaker implantation was significantly higher in patients with a BMI of > 30 (13 vs. 4, p = 0.037). After logistic linear regression, the odds of getting a PPM after TAVR were significantly higher in patients who were overweight (odds ratio (OR): 12.77, p = 0.024; confidence interval (CI): 1.39 – 17.25) and obese (OR: 15.02, p = 0.036, CI: 1.19 – 19.92).

CONCLUSIONS:

Our study demonstrates that increased BMI is a possible risk factor for a high-degree atrioventricular block in patients receiving ESV3.